Search results for "Kovats retention index"

showing 10 items of 17 documents

Floral scent in a sexually deceptive Ophrys orchid: from headspace collections to solvent extractions

2018

Sexually deceptive orchid flowers use visual, tactile and olfactory cues of female insects in order to attract males of one or a few closely related species as pollinators. Ophrys L. is the most species-rich genus of sexually deceptive orchids in the Mediterranean Basin. Despite Ophrys pollinated by Andrena male bees use alkanes and mainly alkenes with specific double-bond positions as key signals that trigger pseudocopulatory behavior, some volatile organic compounds (VOCs) with low molecular weight were found as long-range attractants non-eliciting copulatory behavior. Since floral scents in Ophrys have been extensively studied by solvent extractions here we aimed to understand which flor…

0106 biological sciences0301 basic medicineAndrenapollinationPollinationAndrenaPlant ScienceFlowers01 natural sciencesGas Chromatography-Mass Spectrometry03 medical and health sciencesPollinatorvolatile organic compoundsBotanyOphrys panormitanaOrchidaceaeOphrysOrchidaceaebiologySettore CHIM/06 - Chimica Organicabiology.organism_classificationPseudocopulation030104 developmental biologyOdorantsSettore BIO/03 - Botanica Ambientale E ApplicataKovats retention indexGas chromatography010606 plant biology & botanyResearch Paper
researchProduct

Gas-liquid chromatographic analyses

1983

Abstract The gas chromatography of mixtures of n -alkyl acetates (CH 3 COOR, R = C 1 —C 8 ) and methyl esters of aliphatic n -carboxylic acids (R′COOCH 3 , R′ = C 1 —C 8 ) and certain of their monochlorinated derivatives has been studied on Carbowax 20M and SE-30 glass capillary columns under the same operating conditions. The separation of the isomeric monochlorinated esters was complete on Carbowax 20M, whereas on SE-30 the peaks of 6- and 7-chlorooctyl acetates and methyl (ω − 1)- and (ω − 2)-chlorooctanoates and -nonanoates partly overlapped. The complete separation of the mixtures could not be achieved, however, on Carbowax 20M, in spite of the use of various operating conditions. The …

Aqueous normal-phase chromatographyValeric acidCapillary actionChlorine atomLiquid phasechemistry.chemical_elementAlcoholBiochemistryIsothermal processAnalytical ChemistryHomologous serieschemistry.chemical_compoundChain (algebraic topology)Capillary columnChlorineOrganic chemistryMethyleneChlorine substituentQuartzAlkylchemistry.chemical_classificationPrimary (chemistry)ChromatographyElutionChemistrySubstitution (logic)Organic ChemistryButanoic AcidsReversed-phase chromatographyGeneral MedicineCapillary gas chromatographyChromatographic separationAcyl chainembryonic structuresHalogenNitrocardiovascular systemPolarKovats retention indexGas chromatographyChromatography columnRetention timeGas liquid chromatographicJournal of Chromatography A
researchProduct

Gas—liquid chromatographic analyses

1984

Abstract The gas chromatography (GC) of n -alkyl acetates (CH 3 COOR), chloroacetates (CH 2 ClCOOR), dichloroacetates (CHCl 2 COOR) and trichloroacetates (CCl 3 COOR), where the alcohol chain length (R) varied between 1 and 8, and certain of their monochlorinated derivatives, 176 compounds altogether, has been studied on SE-30 and OV-351 glass capillary columns under the same operating conditions. The isomeric monochlorinated esters are eluted in direct order from the 1- chloro to the ω-chloro isomer, the separation of the isomers being complete on OV- 351. On SE-30, however, the peaks of the 6- and 7-chlorooctyl esters are partly overlapped. The separation of the mixtures of odd- and e…

Capillary actionAnalytical chemistryAlcoholFormyl groupAldehydeBiochemistryAnalytical Chemistrychemistry.chemical_compoundCapillary columnStraight chainpolycyclic compoundsStructural isomerOrganic chemistryMethyleneBenzoic acidchemistry.chemical_classificationPrimary (chemistry)General MedicineCapillary gas chromatographyBoiling pointChromatographic separationSalicylaldehydeNitrobenzoatesPolarlipids (amino acids peptides and proteins)Aliphatic compoundResolution (mass spectrometry)Polarity (physics)Carboxylic acidchemistry.chemical_elementBranching (polymer chemistry)Isothermal processTurn (biochemistry)ChlorinePhenolsQuartzAlkylTetradecaneChlorophenolDegree of unsaturationChromatographyGeminalElutionOrganic ChemistryChloroacetatesComplete resolutionReverse orderChain lengthchemistryChlorobenzeneFunctional groupNitroKovats retention indexNon polarGas chromatographyVicinalGas liquid chromatographicJournal of Chromatography A
researchProduct

Gas—liquid chromatographic analyses

1984

Abstract The gas choromatographic retention behaviour of veratrole and all nine chlorinated veratroles was studied on SE-30 and OV-351 capillary columns. Temperature programming from 100°C at 6°C min−1 and isothermal operation at 140, 160, 180 and 200°C were used. The complete separation of a mixture was obtained on SE-30, the isomers being eluted in order of their degree of chlorination. On OV-351, however, the 3,4,5-trichloro and tetrachloro isomers overlap with temperature programming, being separated at 140, 160 and 200°C. Retention indices and increments of retention indices for each position of substitution are examined and the effect of increasing temperature on retention is discusse…

ChromatographyCapillary columnCapillary actionElutionChemistryOrganic ChemistryKovats retention indexGeneral MedicineGas chromatographyBiochemistryGas liquid chromatographicIsothermal processAnalytical ChemistryJournal of Chromatography A
researchProduct

Gas-liquid chromatographic analyses

1984

A mixture of all nine chlorinated 4-hydroxybenzaldehydes and the parent homologue was separated on a non-polar SE-30 capillary column using various isothermal and temperature-programmed operating conditions. The relative retention data for the compounds are given and the retention indices together with the retention index increments for each position of chlorine substitution are examined. The retention order 3-Cl<parent<2,5-di-Cl<2,3-di-Cl<3,5-di-Cl<2-Cl<2,3,5-tri-Cl<2,3,6-tri-Cl<2,6-di-Cl<tetra-Cl isomer obtained indicates that the effect of the position of substitution on the retention behaviour is greater than that of the number of chlorine atoms. The retention is maximal with 2-Cl and 2…

ChromatographyChemistryOrganic Chemistrychemistry.chemical_elementGeneral MedicineBiochemistryIsothermal processAnalytical ChemistryCapillary columnStationary phaseChlorineKovats retention indexNon polarGas chromatographyGas liquid chromatographicJournal of Chromatography A
researchProduct

Retention increments of isomeric chlorobenzenes

1983

The chlorobenzene isomers are used extensively as intermediates in a wide range of chemical products. More recently their determination in environmental situations has become of considerable importance and chromatographic procedures have been widely reported for their determination in both trace and major amounts. There are over 220 publications in which gas chromatography (GC) has been applied to the analysis of chlorobenzene. However, over 60 o/o of these works refer to the separation of only one isomer. Relatively few publications’-8 consider all the isomers, although the use of both capillary3’ and packedcolumns with polar and non-polar stationary phases has been reported. Temperature p…

ChromatographyElutionOrganic Chemistrychemistry.chemical_elementGeneral MedicineBiochemistryIsothermal processAnalytical Chemistrychemistry.chemical_compoundchemistryChlorobenzeneChemical productsChlorineKovats retention indexPolarGas chromatographyJournal of Chromatography A
researchProduct

Gas—liquid chromatographic analyses

1985

Abstract The gas chromatographic retention behaviour of methylethyl, 1-methylpropyl, 2-methylpropyl, 1,2-dimethylpropyl, 1-methylbutyl and 3-methylbutyl esters of benzoic and o-, m- and p-chlorobenzoic acids on low-polarity (SE-30) and polar (OV-351) capillary columns under several temperature-programmed and isothermal conditions is reported. The retention data and the Kovats retention indices for all 24 components are given and the separation of a complex mixture is discussed. The retention index increments have been used to examine the effects of chain branching and chlorine substitution. The results are compared with those for n-alkyl benzoates and monochlorobenzoates.

ChryseneCapillary actionNitro compoundchemistry.chemical_elementFluoreneBranching (polymer chemistry)BiochemistryIsothermal processAnalytical Chemistrychemistry.chemical_compoundCapillary columnChlorineOrganic chemistryMethyleneAlkylBenzoic acidNaphthalenechemistry.chemical_classificationDegree of unsaturationChromatographyElutionOrganic ChemistryGeneral MedicinePhenanthreneBenzoatesChromatographic separationHydrocarbonchemistryPolarKovats retention indexGas chromatographyGas liquid chromatographicJournal of Chromatography A
researchProduct

Effects of water on gas chromatographic column efficiency measurements applied to on-column injections of volatile aroma compounds

2002

International audience

On columnchemistry.chemical_classificationChromatographybiology[SPI.GPROC] Engineering Sciences [physics]/Chemical and Process EngineeringAnalytical chemistryFiltration and Separation[SDV.IDA] Life Sciences [q-bio]/Food engineeringbiology.organism_classificationAnalytical Chemistrylaw.inventionchemistry.chemical_compoundchemistrylaw[SDV.IDA]Life Sciences [q-bio]/Food engineeringAroma compoundKovats retention indexFlame ionization detectorVolatile organic compound[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process EngineeringGas chromatographyWater contentAromaComputingMilieux_MISCELLANEOUS
researchProduct

Gas—liquid chromatographic analyses

1989

Abstract The retention (I), dispersion (IM) and selectivity (I*) indices of sixteen polychlorinated dibenzo-p-dioxins and fourteen polychlorinated dibenzofurans were determined on a low-polarity HP-5 capillary column using a gas chromatograph connected with an ion-selective detector. IM and I* values were also calculated for all 73 dibenzo-p-dioxins from the di- to the octachloro isomer and for all possible 135 chlorinated dibenzofurans based on the predicted retention index data reported earlier. The effect of the position of chlorination is shown and the results are compared with those for several series of chlorinated aromatics.

Polarity (international relations)ChromatographyCapillary actionChemistryOrganic ChemistryAnalytical chemistryGeneral MedicineMass spectrometryBiochemistryAnalytical ChemistryCapillary columnPolychlorinated Dibenzo-p-dioxinspolycyclic compoundsKovats retention indexheterocyclic compoundsGas chromatographySelectivityDispersion (chemistry)Retention timePolychlorinated dibenzofuransGas liquid chromatographicJournal of Chromatography A
researchProduct

Gas chromatography of homologous esters

1984

Abstract The gas chromatographic retention behaviour of the propanoyl and monochloropropanoyl esters of saturated C3C5 branched-chain and unsaturated C3C6 alcohols on SE-30 and OV-351 capillary columns at several temperatures is reported. Retention index increments at 80 and 120°C show the effect of branching in the alkyl chain and also the effect of unsaturation and of its position in the chain with chlorination at the two possible positions in the acyl chain. The various incremental effects are discussed and compared with the behaviour of the corresponding n-alkyl esters.

Steric effectsCapillary actionCarboxylic acidchemistry.chemical_elementBranching (polymer chemistry)BiochemistryAnalytical ChemistryHomologous serieschemistry.chemical_compoundCapillary columnpolycyclic compoundsChlorineOrganic chemistryChlorine substituentAlkylchemistry.chemical_classificationDegree of unsaturationChromatographyOrganic ChemistryChloroacetatesGeneral MedicinechemistryAcyl chainKovats retention indexNon polarGas chromatographyAliphatic compoundJournal of Chromatography A
researchProduct